Heat exchangers are essential equipment in thermal systems as they enable heat transfer between two or more streams of fluids. Optimization and control of energy are paramount in various engineering applications, including electricity production, cooling, and industries where energy conversion is critical. Familiarity with their types, functioning, and effects on system performance is indispensable due to the inclusion of energy systems.
This report discusses, assesses, and analyzes a selected thermal energy system that uses a heat exchanger in terms of its design, operation, and condition. Additionally, an exergy analysis is performed to identify inefficiencies and potential improvements in system performance. Students looking to enhance their understanding of thermal energy systems and analysis techniques can benefit from expert guidance through Assignment Help in UK, which offers professional support in report writing, technical analysis, and academic research.
The selected system is a domestic hot water heating system, which is applied in residential and industrial firms. It includes a steam-raising boiler, a heat change, and a system of water piping. With the help of a heat exchanger, thermal energy from a hot fluid such as heated water or steam transmits to cold water and gives an optimum supply of hot water (Albert et al. 2022).
This type of system is governed by the process of heat transfer indirectly with no intermingling of fluids. It has a compact structure, relatively simple construction about maintenance as well as relatively good energy utilization characteristics making it suitable for environmentally friendly heating opportunities (Careri et al. 2023).
The heat exchanger in the domestic hot water heating system is the component that facilitates heat transfer from the primary heating fluid to the cold water. The heat exchanger provides the need for heat exchange while at the same time, keeping the two fluids separate from each other. The device controls water temperature to match the demands of the system, improves energy management, and reduces thermal heat dissipation. Further, the efficiency of the overall system is enhanced besides enacting as a barrier, shielding the subsequent components from thermal shocks (Cartelle Barros et al. 2020). The heat exchanger is therefore central to the efficient transfer of thermal energy as well as the general performance of the heat system.
A Plate heat exchanger is chosen to be used in the domestic hot water heating system because of its efficiency, size, and modularity. This type is suitable for applications where heat transfer between fluids is desired but with no internal mixing (Davies et al. 2023). They have a numerous exposed area that allows high heat exchange, including low-equation differential temperature losses.
Get assistance from our PROFESSIONAL ASSIGNMENT WRITERS to receive 100% assured AI-free and high-quality documents on time, ensuring an A+ grade in all subjects.
Cleanliness, serviceability, and expandability of the structure are the advantages that can be associated with the modularity of the structure. Moreover, it is capable of operating under fluctuating flow rates and pressure which defines it as capable of operating in different conditions (Isafiade and Short, 2022). Another basis for choosing the plate heat exchanger is that such equipment is relatively cheap and demonstrates high-strength, typical demands in domestic and industrial sectors.
The chosen plate heat exchanger is characterized by a flat-plate arrangement in small, individual layers, with thin, corrugated plates. The system equilibrates in a counter-flow manner to increase the thermal efficiency of the system. Peculiar characteristics of the design are a heat exchange rate of 20 kW, flow rates of 0.5 kg/s for both hot and cold fluids, and a temperature difference of 30°F (hot fluid) to 40°C (cold fluid) (Jouhara et al. 2023). It is safe to maintain the operating pressure of the system to 1.5 bar for better performance. The plates used to make the plates are stainless steel which enables them to be durable, have high corrosion resistance, and have good thermal conductivity to allow them to operate for many hours continuously.
Exergy analysis refers to a solution that can be used to assess the energy quality and, essentially, its effectiveness by outlining energy losses from irreversibility. It is from the Second law of thermodynamics according to which exergy can be defined as the maximum work achievable from any system as it reaches the state of thermal equilibrium with the environment (Lagoeiro et al. 2022). In this way, by considering the exergy destruction and exergy efficiency, an analyst has a chance to recognize the place and time of the highest inefficiencies. Energy analysis gives information on how the energy is utilized in the system showing more information other than what is obtained in energy balance calculations.
During the analysis of the energy conversion in the system, the heat exchanger element is considered for the amount of exergy loss and the System’s efficiency rate. Hot fluid at 70°C flows through the heat exchanger plates and gives up heat to cold fluid entering at ambient temperature (Li et al. 2021). Temperature losses occur due to the disparity in temperatures of the fluids passing through the cycle; the actual to-theoretical efficiency ratio of the complete system is determined. The exergy loss in the heat exchanger is determined through the entropy difference of both the hot and cold fluids, allowing for the identification of the inefficiencies and the suggested directions for improvement.
Exergy of a Flow Stream
This figure shows how exergy efficiency can be computed in the context of the identified system. Its application shows how exergy efficiency is calculated concerning the energy input as well as the energy output documented utilizing thermodynamic parameters such as temperature, pressure, and mass flow rates. The plot at the same time demonstrates how the performance of the system changes with these parameters like the total energy usage efficiency for the system. The data provided assist in evaluating the heat exchanger system and the possible energy conservation and improvement.
The exergy efficiency has been plotted against the mass flow rate as depicted in Figure 4. It shows how shifts in the flow rate of the working media impact the overall heat-transferring and energy-recovering capacity of the plot. This relationship is essential in determining the flow conditions under which maximum exergy efficiency is achievable. The results suggest that an increased flow rate causes higher energy transfer, but thereafter the rate of change decreases which emphasizes the fact that overly high flow rates may not be effective.
This image was drawn to show the interaction between the heat exchanger system and the required mass flow rate. The curve also reveals this point where the option of the most optimal process conditions can be viewed, and that thereafter the exergy efficiency diminishes, so it should be maximized in practice for the system. That flow rate which represents the best efficiency of energy transfer while using the least energy is known as the optimal rate. The data and the above calculations are once again introduced to show how flow rates, in particular, influence heat exchanger performance, and how it is essential to coordinate these parameters to maximize energy use and minimize heat loss.
The above figure shows the variance of exergy efficiency with the inlet temperature of the hot fluid. Higher exergy efficiencies are characteristic of the system because the temperature of the hot fluid enters the exchanger at higher temperatures than that of the cold fluid, especially where the inlet temperature of the hot fluid is high. This figure displays how the enhancement of heat transfer in the process is determined using a rise in the temperature of the hot fluid. That is, the system also implies that its performance is more optimal at high temperatures in terms of heat transfer between the hot and cold fluids.
A heatmap for the effect of fluctuation in the operational parameters on the exergy efficiency has been provided in Figure 7. The heatmap shows the efficiency of the system at various combinations of temperatures and flow rates to facilitate a general glance at the state of the system under a certain set of conditions. The color gradient shown in the figure reflects the exergy efficiency and the warmer the color appears, the higher the exergy efficiency. Such plots are useful in the determination of regions where the system performs best or in the enhancement of either heat exchanger designs.
Exergy efficiency maps are used and Figure 8 is a map of contours of the exergy efficiency that presents how efficiency changes across two dimensions of parameter space. The lines thus depict varying degrees of efficiency; close lines demonstrate regions marked with big changes in the efficiency range. Concerning the present work, it is possible to consider the following plot for interpreting the changes in the interactions between the variables like the temperature difference and the mass flow rate, and their impact on the system’s power to evaluate the exergy recovery. The contour plot provides useful information to identify heat exchanger performance characteristics based on the chosen operational conditions.
These turbines are important parameters of the domestic hot water heating system containing flow rates, temperature differences, as well as pressure drop to make performance optimization. Analytical investigations are carried out using a parametric study of the hot and cold fluid inlet temperatures and the flow rates to determine the conditions that reduce exergy destruction and increase system efficiency (Marcos et al. 2020). The design of the heat exchanger and number of plates together with the arrangement of the fluid channel also contribute to improved heat transfer with minimal energy loss. The above variables are used in Python to quantify their effects on system performance to make relevant improvements.
2.5 Conclusions
The application of the exergy method for the analysis of the domestic hot water heating system reveals potential losses caused by temperature gradients and unequal flow splits in the heat exchanger. Adjusting the important features including; fluid flow rates, temperature policies, and heat exchanger configuration contributes to the enhanced performance of the system. The content analysis results show that lower exergy destruction improves energy effectiveness and system performance. The findings are that performance improvement techniques, which involve alteration of the operating conditions and the heat exchanger system, can provide a way of achieving lower energy wastage and enhanced sustainability of the heating system to enhance thermal energy efficiency.
References
Introduction Get free samples written by our Top-Notch subject experts for taking assignment help uk from Rapid...View and Download
Introduction Get free samples written by our Top-Notch subject experts for taking assignment help services. As Global...View and Download
Introduction to Object-Oriented Programming Assignment The task was to develop a Java console application for managing student...View and Download
Introduction :UPPSALA model Schweizer and Vahlne Get free samples written by our Top-Notch subject experts for taking assignment...View and Download
Introduction Get free samples written by our Top-Notch subject experts for taking online Assignment...View and Download
Introduction Get free samples written by our Top-Notch subject experts for taking assignment help services. ASOS plc...View and Download